Expansion Module for 200X UNIStim phones

Last Updated : Feb 21, 2019 |
Prolog information
The IP Phone Key Expansion Module (KEM) is a hardware component that connects to IP Phone 2002 and IP Phone 2004 and provides additional line appearances and feature keys.
Up to two IP Phone KEMs can be connected to an IP Phone 2002 or IP Phone 2004. The IP phones themselves support a maximum of 48 additional line or feature keys, which can be attained by using a single 24-key KEM and a shift key on the IP phone, or by using two IP Phone KEMs.

IP Phone 2002

The Shift key of the IP Phone 2002 is not functional for the KEMs. With one KEM, the IP Phone can have up to 24 additional line/feature keys. With two IP Phone KEMs, the IP Phone can have up to 48 additional line/feature keys.

IP Phone 2004

The IP Phone 2004 can have up to 48 additional line/feature keys by using a 24-key KEM and the Shift key functionality. With two IP Phone KEMs, the Shift key functionality does not affect the IP Phone KEMs because the maximum number of line/feature keys is already available.

Expansion Module: 24-key LCD KEM for 20xx series endpoints

  • Up to 24 additional keys:
    • 2002: one KEM
      • CM endpoint configuration:
        • CS1000-Type=2002
        • Button Module Pages=1
        • Buttons-per-Page=24
    • 2004: one KEM
      • CM endpoint configuration:
        • CS1000-Type=2004
        • Button Module Pages=1. The Shift will still allow the KEM to have two pages.
        • Buttons-per-Page=24
  • 25 to 48 additional keys:
    • 2002: two KEMs
      • CM endpoint configuration:
        • CS1000-Type=2002
        • Button Module Pages=2
        • Buttons-per-Page=24
    • 2004: one KEM, using Shift
      • CM endpoint configuration:
        • CS1000-Type=2004
        • Button Module Pages=2
        • Buttons-per-Page=24
          Note that the CM requires the second module page for the shifted module entries even though only one KEM is used.
    • 2004: two KEMs, if not using Shift
      • CM endpoint configuration:
        • CS1000-Type=2004
        • Button Module Pages=2
        • Buttons-per-Page=24
Note that each module is predefined with a size of 24 buttons, numbered 0 to 23 on the module.
Specify the data on the Button Module Pages tab:
  • Page use:
    • The first KEM always uses data from Button Module Page 1. If the endpoint is a 2004 endpoint, it may also use a second page.
    • If two modules are used, the second KEM uses the data from Button Module Page 2.
    • If the station is a 2004 station that can use the Shift button and only one physical KEM is used, and when the KEM is shifted, the KEM uses the data from Button Module Page 2. Both modules must be configured.
  • Button Label: Any custom label name.
  • Button Feature: Select a compatible Communication Manager feature.
  • Argument-1 through Argument-3: Provide the additional data as specified in the Communication Manager feature documentation.