CDR data format - enhanced printer for Communication Manager 4.0 or later

Last Updated : Oct 30, 2012 |
Prolog information
CDR data format - enhanced printer for Communication Manager 4.0 or later
Position
Description
1-2
Time of day-hours
3-4
Time of day-minutes
5
Space
6
Duration-hours
7-8
Duration-minutes
9
Duration-tenths of minutes
10
Space
11
Condition code
12
Space
13-16
IXC code
17
Space
18-21
Access code used
22
Space
23-37
Dialed number
38
Space
39-43
Calling number
44
Space
45-59
Account code
60
Space
61-67
Authorization code
68
Space
69-73
ISDN NSV
74
Space
75
FRL
76
Space
77-79
Incoming circuit ID
80
Space
81-83
Outgoing Circuit ID
84
Space
85
Feature flag
86
Carriage return
87
Line feed