Find answers to your technical questions and learn how to use our products
Search suggestions:
Find answers to your technical questions and learn how to use our products
Search suggestions:
|
Position
|
Description
|
|---|---|
|
1-2
|
Time of day-hours
|
|
3-4
|
Time of day-minutes
|
|
5
|
Duration-hours
|
|
6-7
|
Duration-minutes
|
|
8
|
Duration-tenths of minutes
|
|
9
|
Condition code
|
|
10-13
|
Access code dialed
|
|
14-17
|
Access code used
|
|
18-32
|
Dialed number
|
|
33-42
|
Calling number
|
|
43-57
|
Account code
|
|
58-64
|
Authorization code
|
|
65-66
|
Time in queue
|
|
67
|
FRL
|
|
68-70
|
Incoming circuit ID
|
|
71-73
|
Outgoing circuit ID
|
|
74
|
Feature flag
|
|
75-76
|
Attendant console number
|
|
77-80
|
Incoming TAC
|
|
81-82
|
Node number
|
|
83-87
|
ISDN NSV
|
|
88-89
|
IXC code
|
|
90
|
BCC
|
|
91
|
MA-UUI
|
|
92
|
Resource flag
|
|
93-96
|
Packet count
|
|
97
|
TSC flag
|
|
98-99
|
Bandwidth
|
|
100-105
|
ISDN CC (digits 1-6)
|
|
106-110
|
ISDN CC (digits 7-11)/PPM count (1-5)
|
|
111-114
|
Reserved for future use
|
|
115
|
Carriage return
|
|
116
|
Line feed
|
|
117-119
|
Null
|