CDR data format - int-direct for Communication Manager 4.0 or later

Last Updated : Oct 30, 2012 |
Prolog information
CDR data format - int-direct for Communication Manager 4.0 or later
Position
Description
1-2
Day of month
3-4
Month
5-6
Year
7
Space
8-9
Time of day-hours
10-11
Time of day-minutes
12
Space
13
Duration-hours
14-15
Duration-minutes
16
Duration-tenths of minutes
17
Space
18
Condition code
19
Space
20-22
Access code dialed
23-25
Access code used
26
Space
27-44
Dialed number used
45
Space
46-50
Calling number
51
Space
52-66
Account code
67
Space
68-72
PPM count
73
Space
74-75
Incoming circuit ID
76
Space
77-78
Outgoing circuit ID
79
Carriage return
80
Line feed