CDR data format - int process for Communication Manager 3.x

Last Updated : Oct 30, 2012 |
Prolog information
CDR data format - int process for Communication Manager 3.x
Position
Description
1-2
Format code
3-4
Time of day-hours
5-6
Time of day-minutes
7
Duration-hours
8-9
Duration-minutes
10
Duration-tenths of minutes
11
Space
12
Condition code
13
Space
14-16
Access code dialed
17-19
Access code used
20
Space
21-38
Dialed number (digits 1-18)
39-43
Calling number (digits 1-5)
44
Space
45-59
Account code (digits 1-15)
60
Space
61
IXC
62
FRL
63-65
Space
66-67
Incoming circuit ID (digits 1-2)
68-70
Space
71-72
Outgoing circuit ID (digits 1-2)
73
Space
74-78
PPM count (digits 1-5)
79
Carriage return
80
Line feed
81-83