CDR data format - LSU-expand for Communication Manager 4.0 or later

Last Updated : Oct 30, 2012 |
Prolog information
CDR data format - LSU-expand for Communication Manager 4.0 or later
Position
Description
1-2
Time of day-hours
3-4
Time of day-minutes
5
Space
6
Duration-hours
7-8
Duration-minutes
9
Duration-tenths of minutes
10
Space
11
Condition code
12
Space
13-15
Access code dialed
16-18
Access code used
19
Space
20-34
Dialed number
35
Space
36-39
Calling number
40
Space
41-45
Account code
46
Space
47-53
Authorization code
54-57
Space
58
FRL
59
Space
60
Calling number (1st digit)
61
Space
62-63
Incoming circuit ID (tens, units)
64
Space
65
Feature flag
66
Space
67-68
Outgoing circuit ID (tens, units)
69
Space
70
Outgoing circuit ID (hundreds)
71
Space
72
Incoming circuit ID (hundreds)
73
IXC
74
Carriage return
75
Line feed
76-78
Null