These settings are not mergeable. Changes to these settings will require a reboot of the system.
Field |
Description |
Shared Secret/Confirm Password |
User setting used for authentication. Must be matched at both ends of the tunnel. This password is separate from the PPP authentication parameters defined on the L2TP|Tunnel tab. |
Total Control Retransmission Interval |
Default = 0. Range = 0 to 65535. Time delay before retransmission. |
Receive Window Size |
Default = 4. Range = 0 to 65535. The number of unacknowledged packets allowed. |
Sequence numbers on Data Channel |
Default = On When on, adds sequence numbers to L2TP packets. |
Add checksum on UDP packets |
Default = On. When on, uses checksums to verify L2TP packets. |
Use Hiding |
Default = Off When on, encrypts the tunnel's control channel. |