Use this procedure to configure the external and internal signaling interfaces for your deployment.
For detailed information about signaling interface configuration, see Administering Avaya Session Border Controller.
Procedure
Log on to the EMS web interface with administrator credentials.
In the Device drop-down list, select ASBCE.
To configure the external signaling interface, in the navigation pane, click Network & Flows > Signaling Interface.
Click Add.
In the Name field, enter the name for the external signaling interface (B1).
In the IP Address field, enter the network name and the IP address of the Session Border Controller used by SIP signaling messages traversing the network.
The network name is identified by the interface name and VLAN tag.
Leave the TCP Port field blank.
Leave the UDP Port field blank for a non-tunneled mode.
In the TLS Port field, type 5061.
In the TLS Profile field, select the previously configured TLS profile.
Keep the Enable Shared Control check box cleared.
Leave the Shared Control Port field blank.
Click Finish.
To configure the internal signaling interface, in the navigation pane, click Network & Flows > Signaling Interface.
Click Add.
In the Name field, enter the name for the internal signaling interface (A1).
In the IP Address field, enter the network name and the IP address of the Session Border Controller used by SIP signaling messages traversing the network.
The network name is identified by the interface name and VLAN tag.
Leave the TCP Port field blank.
Leave the UDP Port field blank for a non-tunneled mode.
In the TLS Port field, type 5061.
In the TLS Profile field, select the previously configured TLS profile.