Status LED indicators

Last Updated : Mar 07, 2025 |
Prolog information
Note:
The status LED indicators are always off and only turns on to a solid amber if any error occurs.
Icon
Button
Condition
Resolution
Drive indicator
The indicator turns solid amber if there is a drive error.
  • Check the System Event Log to determine if the drive has an error.
  • Run the appropriate online diagnostics test and restart the system and run embedded diagnostics (ePSA).
  • If the drives are configured in a RAID array, restart the system, and enter the host adapter configuration utility program.
Temperature indicator
The indicator turns solid amber if the system experiences a thermal error (for example, the ambient temperature is out of range or there is a fan failure).
Ensure that none of the following conditions exist:
  • A cooling fan has been removed or has failed.
  • System cover, air/cooling shroud, memory module blank, or back filler bracket is removed.
  • Ambient temperature is too high.
  • External airflow is obstructed.
Electrical indicator
The indicator turns solid amber if the system experiences an electrical error (for example, voltage out of range, or a failed power supply unit (PSU) or voltage regulator).
Check the System Event Log or system messages for the specific issue. If it is due to a problem with the PSU, check the status indicator on the PSU. Reseat the PSU.
Memory indicator
The indicator turns solid amber if a memory error occurs.
Check the System Event Log or system messages for the location of the failed memory. Reseat the memory module.
PCIe indicator
The indicator turns solid amber if a PCIe card experiences an error.
Restart the system. Update any required drivers from Avaya for the PCIe card. Reinstall the card.