Bantam jacks

Last Updated : Nov 01, 2012 |
Prolog information
Six bantam jacks on the faceplate of the MM710 Media Module provide access to the incoming and outgoing T1 signals or E1 signals:
  • SM allows passive monitoring of the incoming line
  • EM allows passive monitoring of the outgoing line
  • SO allows intrusive monitoring of the incoming signal from the network. When used, the SO jack breaks the connection of that signal to the framer
  • EI allows injection of a signal towards the framer. When used, the EI jack isolates the network Rx signal.
  • SI allows injection of a signal towards the network. When used, the SI jack isolates the framer Tx signal from going out to the network.
  • EO allows intrusive monitoring of the signal from the framer. When used, the EO jack breaks the connection of that signal to the network jack RJ48C.