Environmental specifications

Last Updated : Feb 14, 2024 |
Prolog information
Specification
Value
Operating altitude de-rating
All temperature ranges are shown at sea level. An altitude derating of 1°C per 300 m (1.8° per 1,000 ft.) to 3048 m (10,000 ft) is applicable.
Storage
Maximum altitude 12,000m (39,370 ft)
Operating
10°C to 35°C (50°F to 95°F). No direct sunlight allowed.
Shipping
-40°C to 65°C (-40°F to 158°F) with a maximum temperature gradation of 20 °C (36 °F) per hour
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
Storage maximum humidity of 95% is based on a maximum temperature of 45° C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 kPa.
Operating
10% to 80% (non-condensing) with 26 °C (78.8 °F) maximum dew point
Non-operating
5% to 95%