Failover overview

Last Updated : Dec 07, 2016 |
Prolog information
When designing an Experience Portal system, you must take into consideration the results of equipment failure. In addition to the failure of an Experience Portal server (that is Primary EPM, Auxiliary EPM, or MPP), you must also consider the failure of servers that Experience Portal depends on. For example, application servers, speech servers, and telephony servers. Typically, Experience Portal systems are designed to withstand the failure of any single server wherein, you must have enough servers of each type so that the system can continue to process calls and messages at full capacity even if one server goes out of service. Such systems are said to be highly available. Some customers might implement a second complete system at a different location. The purpose of the second system is to handle cases where some large-scale problem such as fire, flood, or power outage takes all the servers in the original system out of service at the same time. This method is known as disaster recovery.