Gateway faults

Last Updated : Jan 26, 2022 |

You can generate and display faults or alarms when S8300 is not inserted into v1, using the set icc-monitoring enable CLI command and by setting the S8300 Monitoring status to Enabled. Set status to Disabled when you are not using the show faults feature.

g450graf-019(develop)# show icc-monitoring 
Slot v1 S8300 Monitoring Status: Enabled
Done!
g450graf-019(develop)# show faults

CURRENTLY ACTIVE FAULTS
--------------------------------------------------------------------------
        + Expected S8300 in v1 not present, 01/13-16:14:24.00

When monitoring status is set to enabled, a log message is displayed similar to the following example, if the S8300 is not in service in the show logging file content output.

<187>Jan 21 16:14:24 g450graf -NoTag: -NoUTC(0 0 0:01:32) 2022 105 1 
mediagateway.g450 | 0 ICC-TRPMAJNA[VOICE-Error: S8300 in slot v1 is NOT 
INSERVICE, ID=e2a214cc8919d0e4ebf0620beb381a53