Firmware specifications

Last Updated : Nov 03, 2023 |
Prolog information

New Comcode numbers for G430 Branch Gateway

Old codes are active for G430 Branch Gateway with the imbedded MP20 and MP80 bundle option.
  • 700503274 : G430 120 channel DSP daughter board – Single MP120 for upgrades
  • 700506957 : G430 MP120 Media Gateway – New bundle no on board MP20 and preinstalled MP120
  • 700506958 : G430 MP120 Media Gateway Non-GSA – New bundle number on board MP20 and preinstalled MP120
  • 700508198 : G430 120 CHANNEL DSP daughter board
  • 700512173 : G430 V3 40 CHANNEL GSA
  • 700512174 : G430 V3 40 CHANNEL NON-GSA

Minimum G430 Branch Gateway firmware requirements

Firmware version
Build
v1a
v2a
(MP120 Preinstalled)
v3
Comments
Recommended Communication Manager version
BGW 10.2
43.9.0
Yes
Yes
Yes
AA 10.2, CM 10.2
AA 10.1.x, CM 10.1.x
AA 10.1, CM 10.1
If your Branch Gateway is running Build 38.20.0 or earlier, you must install Release 7.1.0.4 Build 38.21.2 before upgrading to Build 43.9.0.
BGW 10.1
42.4.0
Yes
Yes
Yes
-
AA 10.1, CM 10.1
AA 8.1.x, CM 8.1.x
AA 8.0.x, CM 8.0.x
You can upgrade to Release 10.1 from Build 42.4.0 and earlier only after installing Release 7.1.0.5 Build 38.21.3.
BGW 8.1
41.9.0
Yes
Yes
Yes
MP120 Support
AA 8.1, CM 8.1
AA 8.0, CM 8.0
AA 7.1.x, CM 7.1.x
AA 7.0.x, CM 7.0.x +
You can upgrade to Release 8.1 from Build 41.9.0 and earlier only after installing Release 7.1.0.3 Build 38.21.1.
BGW 8.0
40.10.0
Yes
Yes
Yes
MP120 Support
AA 8.0, CM 8.0
AA 7.1.x, CM 7.1.x
AA 7.0.x, CM 7.0.x +
AA 6.3.x, CM 6.3.x +
You can upgrade to Release 8.0 from Build 40.10.0 and earlier only after installing Release 7.1.0.3 Build 38.21.1.
BGW 7.1.3
39.12.0
Yes
Yes
Yes
MP120 Support
AA 7.0 FP 1, CM 7.0.1
AA 7.0 FP 1, CM 7.0.1
AA 7.0, CM 7.0+
AA 6.2 FP 4, CM 6.3.6+
AA 7.1, CM 6.3.x, AA 7.0, CM 7.1.2
You can upgrade to Release 7.1.3 from Build 39.12.0 and earlier only after installing Release 7.1.0.3 Build 38.21.1.
BGW 7.1.2
39.x.y
Yes
Yes
No
MP120 Support
AA 7.0 FP 1, CM 7.0.1
AA 7.0 FP 1, CM 7.0.1
AA 7.0, CM 7.0+
AA 6.2 FP 4, CM 6.3.6+
AA 7.1, CM 6.3.x, AA 7.0, CM 7.1.2
You can upgrade to Release 7.1.2 from Build 39.5.0 and earlier only after installing Release 7.1.0.3 Build 38.21.1.
BGW 7.1.0+
38.16.0+
Yes
Yes
No
MP120 Support
AA 7.0 FP 1, CM 7.0.1
AA 7.0 FP 1, CM 7.0.1
AA 7.0, CM 7.0+
AA 6.2 FP 4, CM 6.3.6+
AA 7.1, CM 6.3.x, AA 7.0
Branch Gateway requires a 7.x build (37+) to successfully upgrade to Build 38.8.0 or later. Earlier builds will fail with the Invalid file error type. If Branch Gateway is running 36.x or earlier build, you must upgrade to 37.x.y before upgrading to 38.x.y.
BGW 7.0.1.2
37.41.0
Yes
Yes
No
MP120 Support
AA 7.0 FP 1
BGW 7.0.1.1
37.39.0
Yes
Yes
No
MP120 Support
AA 7.0, CM 7.0
BGW 7.0.1
37.38.0+
Yes
Yes
No
MP120 Support
AA 7.0 FP 1, CM 7.0.1
AA 7.0, CM 7.0+
AA 6.2 FP 4, CM 6.3.6+
BGW 7.0.0.2
37.21.0
Yes
Yes
No
MP120 Support
AA 7.0, CM 7.0
AA 6.2 FP 4 CM 6.3.6+
BGW 7.0.0.1
37.20.0
Yes
Yes
No
MP120 Support
AA 7.0, CM 7.0
AA 6.2 FP 4 CM 6.3.6+
BGW 7.0
37.20.0
Yes
Yes
No
MP120 Support
AA 7.0, CM 7.0
AA 6.2 FP 4 CM 6.3.6+
BGW 6.3.14+
36.18.0
Yes
Yes
No
MP120 Support
CM 6.3.x, AA 7.0
BGW 6.3.7 – 6.3.13
36.16.0+
Yes
Yes
No
MP120 Support
AA 6.2 FP 4 CM 6.3.6+
BGW 6.3.6 JITC
36.x.y
Yes
Yes
No
MP120 Support
AA 6.2 FP 4 CM 6.3.6
AA 6.2 FP3 CM 6.3.2+
(CM supports all 120 channels)
BGW 6.3.5
35.x.y
Yes
Yes
No
MP120 Support V150.1 Features
AA 6.2 FP3 CM 6.3.2+
(CM supports all 120 channels)
BGW 6.3.1
34.6.0
Yes
No
No
No BGW support MP120
AA6.2 FP3 CM6.3.2 – Oct 2013
(CM supports all 120 channels)
BGW 6.3
33.13.0
Yes
No
No
No BGW support MP120
AA 6.2 FP2 CM 6.3 – May 2013
(CM supports all 120 channels)
BGW 6.2.1
32.26.0
Yes
No
No
No BGW support MP120
AA 6.2 FP1 CM 6.2 sp 4 – Dec 2012
(CM blocks more than 105 channels)
BGW 6.1
31.26.0
Yes
No
No
No BGW support MP120
CM 6.0.1
(CM blocks more than 105 channels)