Use this task to add the appropriate information so that the deskphone displays a number in the E.164 format.
Procedure
On the Communication Manager SAT interface, type change public-unknown-numbering n, where n is the extension length, and press Enter.
For example, change public-unknown-numbering 10.
The system displays the NUMBERING - PUBLIC/UNKNOWN FORMAT screen.
In the Ext Len field, type the number of digits in the extension.
In the Ext Code field, type one or more starting digits in the extension.
In the CPN Prefix field, type the digits to be attached as a prefix to the digit string.
Connection type
Server
Numbering format
Country code required?
Plus (+) sign required?
Action
SIP
SM
Full international E.164 number
Yes
Yes
Communication Manager automatically inserts the plus (+) sign
SIP
other
Full international E.164 number
Yes
Yes
The system sets the Prepend ‘+’ to Calling Number field on the Protocol Variation screen of the SIP trunk group to y
SIP
other
National E.164 number
No
No
Not applicable
Non-SIP
other
National E.164 number
No
No
Not applicable
Non-SIP
other
National E.164 number
Yes
No
The system sets the Format field on an ISDN trunk group to intl-pub
In the Total CPN Len field, type the total number of digits that Communication Manager must transmit.
Note:
Communication Manager combines the value of the CPN Prefix field with the extension that matches the entry on the NUMBERING - PUBLIC/UNKNOWN FORMAT screen. If the length of the number is longer than the length defined in the Total CPN Len field, Communication Manager deletes the leading digits from the extension until the length of the number is equal to the length defined in the Total CPN Len field.