South Africa (ens)

Last Updated : Mar 25, 2024 |
Prolog information

General Settings

For details, see General Settings.
Setting
Description
Locale
South Africa (UK English)
Three-Letter Code
ens
Default Emergency Numbers (Basic Edition)
10111, 10177

Tones

For details, see Tones.
Tone
Frequency (Hz)
Cadence (seconds)
Dial Tone
350+450
Continuous
Alt Dial Tone
350+450
(1.0/0.5) on/off
Secondary Dial Tone
Dial Tone
Dial Tone
Busy Tone
400
(0.375/0.375) on/off
Fast Busy
400
(0.375/0.375) on/off
Intercept Busy Tone
400
Continuous
Ring Tone
400+450
(0.4/0.2/0.4/2.0) on/off
Call Waiting Tone
400
(0.1/30.0) on/off
Number Unobtainable Tone
400
Continuous

Analog phone settings

For details, see Analog Phone Settings.
Setting
Value
Configurable
Ring Current Frequency
25 Hz
Minimum Flash Hook Time
25ms
Maximum Flash Hook
350ms
Default Caller Display Type
UK20
Default Message Waiting Indication Type
51 V stepped

Locale-specific behavior

For details, see Locale Specific Behaviors
Setting
Value
Configurable
Companding
a-law
Dialing Timeout
30 seconds from start of dialing
Disconnect Tone
Busy
Disconnect Method
Busy tone disconnect
Display Language
English UK
Feature Phone Clearing
Disconnect Tone
Voicemail Truncation Time
7 seconds
Default Currency
ZAR

Date and time settings

Setting
Value
Configurable
Date/Time Format
dd/mm 24 hour
Default Time Zone
(GMT+02:00) Harare, Pretoria
Daylight Savings Time
No
Default DST Calendar
None

Analog trunk settings

For details, see Analog Trunk Settings.
Setting
Value
Configurable
CLI Type
FSK BELL202
Termination Impedance
220 R + (820 R||115nF)
Balance Impedance
220 R + (820 R||115nF)
Busy Tone Detection
400 Hz 0.5/0.5 seconds
Busy Tone Detection Time
7 seconds.
Disconnect Clear
0.5 seconds
Hook Flash Pulse Width
0.5 seconds
Ring Detection Settings
Persistency: 0.2 seconds
Ring Off Maximum: 5.0 seconds

Application Languages

Phone Languages

For details, see Phone Languages.