United Arab Emirates (aru)

Last Updated : Mar 25, 2024 |
Prolog information

General Settings

For details, see General Settings.
Setting
Description
Locale
United Arab Emirates (UK English)
Three-Letter Code
aru
Default Emergency Numbers (Basic Edition)
112

Tones

For details, see Tones.
Tone
Frequency (Hz)
Cadence (seconds)
Dial Tone
440
Continuous
Alt Dial Tone
440
(1.0/0.5) on/off
Secondary Dial Tone
440+350
Continuous
Busy Tone
400
(0.375/0.375) on/off
Fast Busy
400
(0.4/0.35/0.225/0.525) on/off
Intercept Busy Tone
400
Continuous
Ring Tone
400+450
(0.4/0.2/0.4/2.0) on/off
Call Waiting Tone
400
(0.1/30.0) on/off
Number Unobtainable Tone
400
Continuous

Analog phone settings

For details, see Analog Phone Settings.
Setting
Value
Configurable
Ring Current Frequency
20 Hz
✕
Minimum Flash Hook Time
300ms
✓
Maximum Flash Hook
1000ms
✓
Default Caller Display Type
FSKD
✓
Default Message Waiting Indication Type
On: 101 V on Phone V2 modules and IP500 phone cards, otherwise 81 V
✓

Locale-specific behavior

For details, see Locale Specific Behaviors
Setting
Value
Configurable
Companding
a-law
✓
Dialing Timeout
30 seconds from start of dialing
✕
Disconnect Tone
Number unobtainable
✓
Disconnect Method
Busy tone disconnect
✓
Display Language
English UK
✓
Feature Phone Clearing
Go idle
✓
Voicemail Truncation Time
5 seconds
✓
Default Currency
–
✓

Date and time settings

Setting
Value
Configurable
Date/Time Format
dd/mm 24 hour
✓
Default Time Zone
(GMT+04:00) Abu Dhabi, Muscat
✓
Daylight Savings Time
No
✓
Default DST Calendar
None
✓

Analog trunk settings

For details, see Analog Trunk Settings.
Setting
Value
Configurable
CLI Type
FSK BELL202
✓
Termination Impedance
600 R
✓
Balance Impedance
600 R
✓
Busy Tone Detection
425 Hz 0.375/0.375 seconds
✓
Busy Tone Detection Time
7 seconds.
✕
Disconnect Clear
0.46 seconds
✓
Hook Flash Pulse Width
0.46 seconds
✓
Ring Detection Settings
Persistency: 0.25 seconds
Ring Off Maximum: 2.5 seconds
✓

Application Languages

Phone Languages

For details, see Phone Languages.