Switzerland (des/frs/its)

Last Updated : Mar 25, 2024 |
Prolog information

General Settings

For details, see General Settings.
Setting
Description
Locale
Switzerland (French)
Switzerland (German)
Switzerland (Italian)
Three-Letter Code
frs
des
its
Default Emergency Numbers (Basic Edition)
None

Tones

For details, see Tones.
Tone
Frequency (Hz)
Cadence (seconds)
Dial Tone
425
Continuous
Alt Dial Tone
425
(1.0/0.5) on/off
Secondary Dial Tone
Dial Tone
Dial Tone
Busy Tone
425
(0.5/0.5) on/off
Fast Busy
425
(0.5/0.5) on/off
Intercept Busy Tone
425
(0.2/0.2) on/off
Ring Tone
425
(1.0/4.0) on/off
Call Waiting Tone
425
(0.2/0.2/0.2/4.0) on/off
Number Unobtainable Tone
425
(0.2/0.2) on/off

Analog phone settings

For details, see Analog Phone Settings.
Setting
Value
Configurable
Ring Current Frequency
25 Hz
✕
Minimum Flash Hook Time
25ms
✓
Maximum Flash Hook
350ms
✓
Default Caller Display Type
UK20
✓
Default Message Waiting Indication Type
On: 101 V on Phone V2 modules and IP500 phone cards, otherwise 81 V
✓

Locale-specific behavior

For details, see Locale Specific Behaviors
Setting
Value
Configurable
Companding
a-law
✓
Dialing Timeout
30 seconds from start of dialing
✕
Disconnect Tone
Busy
✓
Disconnect Method
Busy tone disconnect
✓
Display Language
French, Italian or German depending on specific selected locale
✓
Feature Phone Clearing
Disconnect Tone
✓
Voicemail Truncation Time
7 seconds
✓
Default Currency
CHF
✓

Date and time settings

Setting
Value
Configurable
Date/Time Format
dd/mm 24 hour
✓
Default Time Zone
(GMT+01:00) Belgrade, Bratislava, Budapest, Ljubljana, Prague
✓
Daylight Savings Time
On
✓
Default DST Calendar
  • Start: 1 am. End: 1 am.
  • 31 March 2024 - 27 October 2024
  • 30 March 2025 - 26 October 2025
  • 29 March 2026 - 25 October 2026
  • 28 March 2027 - 31 October 2027
  • 26 March 2028 - 20 October 2028
  • 25 March 2029 - 28 October 2029
  • 31 March 2030 - 27 October 2030
  • 30 March 2031 - 26 October 2031
  • 28 March 2032 - 31 October 2032
  • 27 March 2033 - 30 October 2033
✓

Analog trunk settings

For details, see Analog Trunk Settings.
Setting
Value
Configurable
CLI Type
FSK BELL202
✓
Termination Impedance
220 R + (820 R||115nF)
✓
Balance Impedance
220 R + (820 R||115nF)
✓
Busy Tone Detection
425 Hz 0.5/0.5 seconds
✓
Busy Tone Detection Time
7 seconds.
✕
Disconnect Clear
0.5 seconds
✓
Hook Flash Pulse Width
0.5 seconds
✓
Ring Detection Settings
Persistency: 0.4 seconds
Ring Off Maximum: 5.0 seconds
✓

Application Languages

Phone Languages