External interfaces on the CO trunk side for the MM711 Analog Media Module

Last Updated : Nov 01, 2012 |

The following requirements apply to the external interfaces on the CO trunk side:

  • The tip and ring default input impedance is 600 Ohms. The default impedance can be configured to accommodate other tip and ring impedances. One such impedance is the 900 Ohms that is used in Brazil. Another is the complex impedance that is used in the European Union.

  • A hard-wired ground wire is added for each IROB-to-earth ground.

  • The MM711 supports DTMF, MF, and pulsing.

  • The MM711 supports R2MFC address signaling and provides -48 VDC for ports that are set up as direct inward dialing (DID).

  • The acceptable loop range for the CO trunk is 18 to 60 mA.

  • The MM711 supports direct inward and outward dialing (DIOD) for Japan.

MM711 supports the following trunk types:

  • Loop-start and ground-start CO trunks

  • DID

  • CAMA