Signal timing specifications for the MM712 support TDM bus timing in receive and transmit modes. The gateway supplies only +5 VDC and –48 VDC to the MM712 Media Module. Any other required voltages must be derived on the module.

MM712 provides loop range secondary protection. The MM712 is also self-protecting from an over-current condition on a tip and ring interface. The MM712 supports the following loop length:

  • 5500 feet (1676 meters) over 0.65 mm (.025 in.) wire (22 AWG)

  • 3500 feet (1067 meters) over 0.5 mm (.02 in.) wire (24 AWG)

  • 2200 (671 meters) over 0.4 mm (.016 in.) wire (26 AWG)

Danger:

The ports on the MM712 are intended for in-building use only. Telephone lines connected to those ports are not to be routed out-of-building. Failure to comply with this restriction could cause harm to personnel or equipment.