Provisioned Base Station Configuration

Last Updated : Nov 21, 2023 |

About this task

For a provisioned installation, the master base station needs to be configured to accept a provisioning connection from the failover system.

Procedure

  1. Login to the master base station.

    This process requires access to tabs and fields currently only visible when Show Advanced Options is selected.

  2. Select Services and then select the Provisioning tab.
  3. Set the Current View to Redundant.
    1. Select the Enable option.
    2. The IP Office security settings control whether HTTPS is supported between the master base station (by default it is supported) and the failover IP Office system.
    3. Set the PBX IP Address to match the failover IP Office system.
    4. In the User Name and Password fields, set the details that match the failover IP Office system's service user configured for IP DECT.
    5. Ensure that the Base directory is set to /system/backupipdect/ instead of /system/ipdect/.
    6. Click OK.
  4. Reset the base station.
    1. Click on Reset required if displayed. Otherwise, select Reset and then select the Reset tab.
    2. Click OK.

      Depending on your base station, wait for the lower LED to return to solid blue or solid green.