In deployments with
Avaya Aura® System Manager geographic redundancy set up, the
IP Office devices added in the primary
System Manager are also visible in the secondary
System Manager. To use
Avaya Aura® System Manager geographic redundancy in the
IP Office Branch solution, make sure:
-
The initial interactions through the SCEP protocol are done between the IP Office and the primary System Manager to establish trust.
-
The IP address for the primary and secondary System Manager are configured as trap destinations in the IP Office. This way, IP Office sends alarms and traps to both System Manager servers. When the primary System Manager server is down, the secondary System Manager server still receives this information.
If the
IP Office is using
Avaya WebLM centralized licensing and the connection between the
IP Office and the
Avaya WebLM server on the primary
System Manager is down, then the
IP Office goes into
WebLM Error Mode. In this mode, all functionality is available for a grace period of 30 days. No action is required if the
Avaya WebLM server on the primary
System Manager is active and reachable in less than 30 days. If there is a risk of the
System Manager server not being available for 30 days, you must modify the
IP Office configuration to use the
Avaya WebLM server on the secondary
System Manager as soon as possible.