Italy (ita)

Last Updated : Mar 25, 2024 |

General Settings

For details, see General Settings.

Setting

Description

Locale

Italy (Italian)

Three-Letter Code

ita

Default Emergency Numbers (Basic Edition)

None

Tones

For details, see Tones.

Tone

Frequency (Hz)

Cadence (seconds)

Dial Tone

350+425

Continuous

Alt Dial Tone

350+425

(1.0/0.5) on/off

Secondary Dial Tone

425

(0.2/0.2/0.6/1.0) on/off

Busy Tone

400

(0.5/0.5) on/off

Fast Busy

400

(0.5/0.5) on/off

Intercept Busy Tone

400

(0.5/0.5) on/off

Ring Tone

425

(1.0/4.0) on/off

Call Waiting Tone

400

(0.1/4.9) on/off

Number Unobtainable Tone

425

(0.1/0.1) on/off

Analog phone settings

For details, see Analog Phone Settings.

Setting

Value

Configurable

Ring Current Frequency

25 Hz

Minimum Flash Hook Time

25ms

Maximum Flash Hook

350ms

Default Caller Display Type

FSKD

Default Message Waiting Indication Type

On: 101 V on Phone V2 modules and IP500 phone cards, otherwise 81 V

Locale-specific behavior

For details, see Locale Specific Behaviors

Setting

Value

Configurable

Companding

a-law

Dialing Timeout

10 seconds with no digit dialed

Disconnect Tone

Number unobtainable

Disconnect Method

Busy tone disconnect

Display Language

Italian

Feature Phone Clearing

Go idle

Voicemail Truncation Time

2 seconds

Default Currency

EUR

Date and time settings

For details, see Timezones and daylight savings time.

Setting

Value

Configurable

Date/Time Format

dd/mm 24 hour

Default Time Zone

(GMT+01:00) Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna

Daylight Savings Time

On

Default DST Calendar

  • Start: 1 am. End: 1 am.

  • 31 March 2024 - 27 October 2024

  • 30 March 2025 - 26 October 2025

  • 29 March 2026 - 25 October 2026

  • 28 March 2027 - 31 October 2027

  • 26 March 2028 - 20 October 2028

  • 25 March 2029 - 28 October 2029

  • 31 March 2030 - 27 October 2030

  • 30 March 2031 - 26 October 2031

  • 28 March 2032 - 31 October 2032

  • 27 March 2033 - 30 October 2033

Analog trunk settings

For details, see Analog Trunk Settings.

Setting

Value

Configurable

CLI Type

FSK BELL202

Termination Impedance

200 R + (820 R||115nF)

Balance Impedance

200 R + (820 R||115nF)

Busy Tone Detection

425 Hz 0.5/0.5 seconds

Busy Tone Detection Time

2 seconds.

Disconnect Clear

0.5 seconds

Hook Flash Pulse Width

0.5 seconds

Ring Detection Settings

Persistency: 0.4 seconds

Ring Off Maximum: 5.0 seconds

Application Languages

For details, see IP Office Application Languages.

Phone Languages

For details, see Phone Languages.