Default Security Settings

Last Updated : Jan 13, 2023 |
Prolog information
Defaults values for IP Office security settings are loaded on first start-up and on reset. They have a level of security and include enforced password changes for accounts.
It is possible to reset the IP Office security settings via a management interface, IP500 V2 serial port or power-on reset buttons; for this reason it is important to make the IP Office installation physically secure.
The following default security settings are applied to the various IP Office service interfaces.
Interface
Default Setting
Default Security?
Notes
Configuration
Secure, Medium
IP Office Manager configuration access
Security Administration
Secure, Medium
IP Office Manager security settings access
System Status Application Interface
Secure, Medium
SSA access
Enhanced TSPI
Secure, Medium
Avaya one-X® Portal for IP Office CTI access
HTTP
Unsecure + Secure
Phone and IP Office Manager file access, Voicemail Pro, IP Office Line, System Monitor (secure)
Web Services
Secure, Medium
IP Office Manager and SMGR
TFTP Server
Active (IP500 V2) Inactive (Linux)
Allows access for IP Office Manager upgrade and UDP whois discovery
TFTP Directory Read
Inactive
n/a
DECT R4 system directory
TFTP Voicemail
Inactive
n/a
Used for Voicemail Pro R9.0 and prior
Program Code
Active (IP500 V2) Inactive (Linux)
IP Office Manager upgrade access
Devlink
Inactive
n/a
DevLink and System Monitor UDP/TCP access
Devlink3
Active
DevLink3 access
TAPI
Inactive
n/a
1st and 3rd party TAPI interfaces only
HTTP Directory Read
Active
Avaya one-X® Portal for IP Office directory access, external directory feature
HTTP Directory Write
Active
Avaya one-X® Portal for IP Office directory access
The local security settings for Avaya one-X® Portal for IP Office and Voicemail Pro may be reset using the Linux console CLI and root access.