SysMonitor has a number of connection methods: Two legacy (UDP and TCP), and two contemporary (HTTP and HTTPS). Only the HTTPS method is fully secure, but has the highest processing overhead. UDP has the least.
IP Office support of the various SysMonitor connection methods is controlled by the security settings as follows:
HTTP Service Security Level
HTTP
HTTPS
UDP
TCP
Disabled
Disabled
Disabled
n/a
n/a
Unsecure Only
Enabled
Disabled
n/a
n/a
Unsecure + Secure
Enabled
Enabled
n/a
n/a
Secure Low
Disabled
Enabled
n/a
n/a
Secure Medium
Disabled
Enabled
n/a
n/a
Secure High
Disabled
Enabled
n/a
n/a
Unsecured Interfaces | DevLink
HTTP
HTTPS
UDP
TCP
Disabled
Disabled
Enabled
Disabled
Disabled
Enabled
Enabled
Enabled
Enabled
Enabled
  1. A Service User account should be used rather than the legacy Monitor Password, the IP Office Manager security using the setting SystemUnsecured InterfacesUse Service User Credentials. For default accounts that can use SysMonitor in this way, see Default Administrative Users and Rights Groups.
  2. The legacy UDP and TCP connection methods should be disabled via the Manager security setting SystemUnsecured InterfacesDevlink.
    ADDITIONAL INFORMATION:
    • Note: If the legacy connection methods are not disabled, the password exchange between SysMonitor and IP Office is unsecure.
  3. Select the correct connection methods in the SysMonitor FileSelect Unit tab. If HTTPS is used, an identity certificate (certificate plus private key) is requested. This is used by SysMonitor to identify itself. For more information about certificates and PKI, see Certificates and Trust.
  4. To ensure only HTTPS is used, the IP Office Manager security setting ServicesHTTPService Security Level should be set to disable HTTP.
    ADDITIONAL INFORMATION:
    • Note: The IP Office HTTP service is used by many components including H323 phones, IP Office lines,IP Office SoftConsole, Voicemail Pro and Avaya one-X® Portal for IP Office.