SIP sessions belonging to this tenant use a SIP server, for example, a SIP PBX. Use this procedure to configure Avaya SBC with the contact details for this SIP trunk server.
Procedure
On the EMS web interface, in the navigation pane, click SBC.
In the navigation pane, click Services > SIP Servers.
The EMS server displays the SIP servers page.
Click Add.
In the Profile Name field, enter tenant1_trunk_server.
Click Next.
In the Server type, select Trunk Server.
In the IP Address/FQDN field, enter 192.168.101.20.
In the Port field, enter 5060.
In the Transport field, enter TCP.
Click Next.
In the Edit SIP Server Profile - Authentication page, leave the default values and click Next.
In the Edit SIP Server Profile - Heartbeat page, leave the default values and click Next.
In the Edit SIP Server Profile - Registration page, leave the default values and click Next.
In the Edit SIP Server Profile - Ping page, leave the default values and click Next.
In the Edit SIP Server Profile - Advanced page, leave the default values and click Finish.