Configuring the tenant network for carrier trunk traffic

Last Updated : May 29, 2023 |
Prolog information
Use this procedure to configure an address on A2 interface to support  SIP trunk traffic to and from the carrier PSTN gateway for Avaya SBC.
  1. On the EMS web interface, in the navigation pane, click SBC.
  2. In the navigation pane, click Network & FlowsNetwork Management.
    STEP RESULT:
    The EMS server displays the Network Management page.
  3. On the Network Management page, click the Networks tab.
  4. In the Name field, enter A2-carrier-trunk.
  5. In the Gateway field, enter 10.10.1.1.
  6. In the Subnet mask field, enter 255.255.255.0.
  7. In the Interface field, select A2.
  8. In the IP address field, enter 10.10.1.20.
  9. Click Finish.