Configuring the SIP server network

Last Updated : May 29, 2023 |
Prolog information
Use this procedure to configure an address on B1 for communicating with the SIP server for Avaya SBC.
  1. On the EMS web interface, in the navigation pane, click SBC.
  2. In the navigation pane, click Network & Flows Network Management .
    STEP RESULT:
    The EMS server displays the Network Management page.
  3. On the Network Management page, click Networks tab.
  4. In the Name field, enter SIPServer1_network.
  5. Click Add.
  6. In the Gateway field, enter 192.168.1.1.
  7. In the Subnet mask field, enter 255.255.255.0.
  8. In the Interface field, select B1.
  9. In the IP address field, enter 192.168.1.10.
  10. Click Finish.