ESM Hourly report and ESM Summary report field descriptions

Last Updated : Aug 03, 2014 |
Prolog information
Name
Description
Peak Hour For All ESM-MMIs
The measurement hour with the highest usage for the ESM-MMI ports.
Meas Hour
The starting time of the hour during which the data is recorded.
Avail Ports
The number of ESM-MMI ports.
Avail Usage
The time that the ESM-MMI ports are available.
Total Usage
The time that the ESM-MMI ports are in use during the measurement period. The time is measured from the time the port is allocated until the port is released, including the time that the ports are out of service or are used for maintenance.
Total Alloc
The number of times that an ESM-MMI port is allocated to a call.
ESM Denials
The number of times that an ESM-MMI port is required for a call, but is unavailable.
Out of Srv-CCS
The time that the ESM-MMI ports are out of service during the measurement period.
%APB
The percentage of time that all ESM-MMI ports are unavailable during the measured period.
% Blockage
The percentage of attempted allocations of the ESM-MMI ports that are unsuccessful. This value is calculated as:
% blockage = (ESM Denials / Total Alloc + ESM Denials) * 100