The IP addresses in the following examples refer to the nodes where the command is unsuccessful:
135.60.84.135: Error occurred while running script Configuring SIP listening port on all system nodes. No response received. Check node status.
135.60.84.134: Error occurred while running script Configuring SIP listening port on all system nodes. No output received within a timeout of 600000 ms.
Cause
The messages, such as the port being already in use or other system errors indicates a problem while configuring the SIP listening port.
Solution
On the current Avaya Hybrid Cloud Gateway system, use the cdto logs command to go to the logs directory.
Locate the CSA_utility.logs file.
Review the detailed error messages.
After identifying and resolving the issue, retry the command to configure the SIP listening port.