logfilter

Last Updated : Nov 01, 2012 |
Prolog information

Syntax

logfilter   [-o] [-a] [-d] [-s] [-l level] [-t type] processname | all  
logfilter   [-h] [-?]
-o
OR in the mask for which levels and types of messages will be logged. The mask can be entered in decimal, octal (preceded by ’0’), or hex (preceded by ’0x).
-a
AND in the mask for which levels and types of messages will be logged. The mask can be entered in decimal, octal (preceded by ’0’), or hex (preceded by ’0x).
-d
Reset the debugging level and type to the original default.
-s
Display a summary of the debugging level and type.
-l level
Sets the mask for which levels of messages will be logged. The mask can be entered in decimal, octal (preceded by ’0’), or hex (preceded by ’0x).
-t type
Sets the mask for which types of messages will be logged. The mask can be entered in decimal, octal (preceded by ’0’), or hex (preceded by ’0x).
-? | -h
Display the usage statement.

Description

Use logfilter to selectively turn on or off the logging-specific types of messages as well as specific levels of messages for a specific process or all processes. If either the level or type mask is not specified, then its value is left the same. If neither are specified, then the current value of each for each specified process is displayed.