Find answers to your technical questions and learn how to use our products
Search suggestions:
Find answers to your technical questions and learn how to use our products
Search suggestions:
display errors [ high-resolution ] [ schedule ]
|
Field
|
Description
|
|---|---|
|
Error Type
|
The report can be restricted to specific error codes. Default is every error.
|
|
Error List
|
The report can be restricted to errors from one of three lists described below: active-alarms, errors, or cleared-errors. Default is active-alarms.
|
|
Interval
|
Specifies error records for the last month, hour, day, week, or all errors (m, h, d, w, a). The default is all.
|
|
From
|
Specifies error records starting from the time specified by (month/day/hour/minute). If no From date is entered, errors from the earliest record in the log are displayed.
|
|
To
|
Specifies every error record up to the time specified by mm/dd/hh/mm. If no To date is entered, every error up to the current date appears.
|
|
Equipment Type
|
To limit the report to a specific group of components, enter the location of a type of equipment in one of the following fields. If no entry is made, errors for the entire system are displayed.
|
|
Field
|
Description
|
|---|---|
|
Port
|
The physical location of the alarmed object.
|
|
Maintenance Name
|
The name of the MO as it appears in the alarm and error logs.
|
|
The alternate name depends upon the type of the object. For example:
|
|
|
Error Type
|
Numerical error code that identifies the type of problem. The meanings of these codes are explained under the name of the MO in the Maintenance Commands for Avaya Aura® Communication Manager, Branch Gateways and Servers.
|
|
Aux Data
|
Additional numerical information about the error type. Only the most recent auxiliary data for each error type appears.
|
|
First line: Month, day, hour, and minute (and second, if the high-resolution command-line option is used) that the error was first recorded.
Second line: The month, day, hour, and minute (and second, if the high-resolution command-line option is used) of the most recent error. If the system is unable to retrieve the time of day when the error occurred, a dummy date will be stamped in the log so as to distinguish it from reliable data. It appears as 00/00/01:07.
|
|
|
Seq Cnt
|
Sequence Count. These numbers give the order in which the errors were logged. Each sequence covers a period of one second. Sequence numbers are assigned to the first and last occurrences of a given error within the one second period given in the time stamp. There may be gaps in the sequence numbers within a given second because the last occurrence of an error may replace an existing entry and because sequence numbers are also assigned to software events not shown in the hardware error log. This information appears when the high-resolution option is specified on the command line.
|
|
Err Cnt
|
The total number of times that the error type has occurred. The maximum entry is 999.
|
|
Err Rt
|
Average hourly rate at which the error has occurred from the first occurrence to the present. The maximum entry is 999.
|
|
Rt/Hr
|
An approximation of the rate at which this error occurred in the last hour. The maximum entry displayed is 999.
|
|
Al St
|
Alarm Status. A character indicating the status of this MO in the error and alarm logs.
|
|
Ac
|
y/n — Whether the maintenance object is still under active consideration by the maintenance subsystem.
|