test customer-alarm

Last Updated : Aug 14, 2023 |
Use test customer-alarm to test the customer provided alarm device by closing the alarm relay contact on the PN and EPN maintenance media module in a specified cabinet, including the TN2312BP, for 1 minute and then restoring the alarm relay contact to its current state. Verify the test by checking the customer alarm attached to the specified media module.
Prolog information

Syntax

test customer-alarm  UU C [ short | long  ][ repeat # | clear ][ schedule ]
location UU C
Extension of the data module or data channel to be tested, per dial-plan.
short
Execute a series of nondestructive diagnostic tests.
long
Execute a more comprehensive and longer version of the diagnostic tests. This may involve both destructive and nondestructive tests.
repeat #
Number of times to repeat the test.
clear
Repeat the test sequence until the alarm is cleared, or until a single test in the sequence fails.
schedule
Specify a start time for the command.

Example

test customer-alarm 
test customer-alarm  02  r  2
test customer-alarm  01b  r  25
test customer-alarm  2a 
test customer-alarm  2a  sh 
test customer-alarm  3  c