test data-module

Last Updated : May 01, 2013 |
Use test data-module to perform hardware diagnostic tests on a data module or a data channel. Test results are determined by the interface to the digital switch-data line port, digital line port, or network control data channel.
Prolog information

Syntax

test data-module  extension  [ short  |  long ][ repeat  #  |  clear ] [ schedule ] 
extension
Extension of the data module to be tested (per dial-plan).
short
Execute a series of nondestructive diagnostic tests.
long
Execute a more comprehensive and longer version of the diagnostic tests. This may involve both destructive and nondestructive tests.
repeat #
Number of times to repeat the test.
clear
Repeat the test sequence until the alarm is cleared, or until a single test in the sequence fails.
schedule
Specify a start time for the command.

Example

test data-module 30000  l
test data-module 30000 
test data-module 32000  sh  r  2
test data-module 33000  l  r 25
test data-module 30000  c