status access-endpoint

Last Updated : Aug 14, 2023 |
Use the status access-endpoint command to check the operational status of an access endpoint.
Prolog information

Syntax

status access-endpoint extension 
extension
The extension of the access endpoint.

Field descriptions

Field
Description
Extension
The extension number of the access endpoint.
Port
The physical location of the port, including media gateway, slot, and circuit, to which the access endpoint is connected.
Note:
For the wideband access endpoint, the location is the starting port.
Communication Type
The type of communication that the channel supports. Values of this field include:
  • 56k-data
  • 64k-data
  • voice-band-data
  • voice-grade-data
  • wideband
Width
The width of the access endpoint
For communication types 56k-data, 64k-data, voice-band-data, and voice-grade-data, the width is 1
For communication type wideband, the width is the number of DS0s that make up the access endpoint
Service State
The operational status of the access endpoint channel. Values of this field include:
  • in-service or active
  • in-service or idle
  • out-of-service
  • maintenance-busy
  • disconnected
Connected Ports
The location of any facility or endpoint to which this access endpoint is connected.