test ds1-facility

Last Updated : Aug 08, 2023 |
Use test ds1-facility to perform a series of tests on the specified facility. Each test runs diagnostics on the facility and returns results of the test along with any possible error codes. The long test is destructive and is not enabled unless the facility has been busied out.
Prolog information

Syntax

test ds1-facility location [ short  |  long  |  external loopback ][ repeat # ] [ schedule ]
location
Location of the DS1 Converter media module.
short
Run a series of nondestructive diagnostic tests.
long
Run a more comprehensive and longer version of the diagnostic tests. This may involve both destructive and nondestructive tests.
external loopback
This initiates a destructive test that sends a test pattern to an external device and returns it for comparison to the original. Configure the external device to loop back the signal. For more information, see Maintenance Alarms for Avaya Aura® Communication Manager, Branch Gateways Servers
repeat #
Number of times to repeat the test.
schedule
Specify a start time for the command.

Example

test ds1-facility 1v902