Synchronous method

Last Updated : Apr 23, 2014 |
Prolog information
One command is used in this method to start, stop, and query an ISDN-PRI test call. In the synchronous method, an outgoing ISDN-PRI test call may be part of one of the following long test sequences entered at the terminal:
  • test trunk grp/mbr long [repeat#]
  • test port location long [repeat#]
  • test board location long [repeat#]
The long qualifier must be entered in the above commands for the ISDN test call to run. The repeat number (#) can be any number from 1 through 99 (default = 1).
The following information is displayed in response to the above commands:
  • Port: The port address (location) is the PN’s number, carrier designation, slot, and circuit of the maintenance object (MO) under test.
  • Maintenance Name: The type of MO tested.
  • Test Number: The actual test that was run.
  • Test Results: Indicates whether the test passes, fails, or aborts.
  • Error Code: Additional information about the results of the test. For details, see ISDN-TRK (DS1 ISDN Trunk).