Maintenance features for G450 Branch Gateway and G430 Branch Gateway

Last Updated : Jan 08, 2024 |
Prolog information
Maintenance features for G450 Branch Gateway and G430 Branch Gateway
Supported feature
Controller Duplicated Servers
Notes
Attendant Console alarm LED and alarm report acknowledgement LED
Yes
Status of G450 Branch Gateway and G430 Branch Gateway alarms is not available on the Attendant Console with a legacy controller.
Automatic Trunk Measurement System (ATMS)
No
Not available for analog trunks terminating on a Media Module.
This test aborts when attempting a test call on these trunk groups:
  • ISDN-PRI
  • SIP
  • DID
  • Any incoming trunk group (transmission tests can only be run on outgoing trunks)
DS0 Looparound connection
No
DS1 CPE Loopback
Yes
Test is controlled by the DS1 Media Module.
DS1 Synchronization
Yes
Synchronization can be controlled by the Communication Manager server or locally on the G430 Branch Gateway and G450 Branch Gateway.
Enable/Disable Media Module tests
Yes
Enable/Suspend alarm origination
No
Not supported by Duplicated Server platform.
ISDN loop around connection
Yes
ISDN test call
No
Not available for ISDN trunks terminating on a DS1 Media Module.
LED tests
Partial
Works with Media Module LEDs but not with G430 Branch Gateway and G450 Branch Gateway alarm LED.
System Configuration Maintenance Object
No
Not needed for Media Module board insertion. Indicates that a board is present but that the board does not respond to a query for board type.
System Link test for PRI control link for ISDN DS1 Media Module
No
Layer 2 of a PRI link is terminated in G430 Branch Gateway and G450 Branch Gateway. A new MO is added for the status and alarming of H.248 links.
System tone test call for G430 Branch Gateway and G450 Branch Gateway
No
Requires changes to the call processing software in the G450 Branch Gateway and G430 Branch Gateway.
TDM Time Slot test call
No
Terminating Trunk Transmission test
No
Test MO command
Yes
Support syntax of Media Module location
Test of G450 Branch Gateway and G430 Branch Gateway resources:
Archangel
Network Control Element
Packet Interface
TDM clock
Tone generator
Tone detectors
No
Provided by G450 Branch Gateway and G430 Branch Gateway. G450 Branch Gateway and G430 Branch Gateway architecture specifies these resources as G450 Branch Gateway and G430 Branch Gateway resources.
Tests of Media Modules
Partial
Touch Tone Receiver facility test call
No
TTRs in G450 Branch Gateway and G430 Branch Gateway are not available outside the gateway.
Touch Tone Receiver level
No
TTRs in G450 Branch Gateway and G430 Branch Gateway are not available outside the gateway.
Trunk facility test call
Yes
Write Physical Angel command
No
System synchronization
Yes