In this screen trunk groups 1-100 report alarms to the Alarm Log in the following ways:
-
Trunk groups 1-25 are assigned to Alarm Group 1: On-board alarms report as-is (major and minor). See the
On-board Trunk Alarms (Alarm Group 1) field in
Set options form). Both major and minor off-board alarms are downgraded to the warning alarms.
-
Trunk groups 26-50 are assigned to Alarm Group 2: Major on-board alarms report as minor alarms, and minor alarms report as warning alarms (
On-board Trunk Alarms (Alarm Group 2) field in
Set options form). Both major and minor off-board alarms are downgraded to warning alarms.
-
Trunk groups 51-75 are assigned to Alarm Group 3: Major on-board alarms report as-is to the Alarm Log, and minor alarms report as warning alarms (
On-board Trunk Alarms (Alarm Group 3) field in
Set options form). Both major and minor off-board alarms are downgraded to warning alarms.
-
Trunk groups 76-100 are assigned to Alarm Group 4: Major on-board alarms are not reported to the Alarm Log, and minor alarms report as warning alarms (
On-board Trunk Alarms (Alarm Group 4) field in
Set options form). Both major and minor off-board alarms are downgraded to warning alarms.