frame-relay interface-dlci

Last Updated : Nov 06, 2012 |
Associates a frame relay Virtual Channel with the current interface. This VC will be in the primary role (that is, will determine the operational status of the interface). Use no frame-relay interface-dlci to delete the association of the VC and the sub-interface and to replace the currently configured interface-DLCI.
Prolog information
Use the optional type parameter to set the encapsulation type. By default, the Frame Relay sub-interface inherits its encapsulation type from the Frame Relay interface encapsulation type.

Syntax

[no] frame-relay interface-dlci DLCI_number [type]

Parameters

Parameter
Description
Possible Values
Default Value
DLCI_number
The Virtual Channel DLCI
16-1007
type
The encapsulation type
IETF (RFC1490/RFC2427), non-IETF
IETF
Note:
Non-IETF encapsulation is compatible with other vendors.

User level

read-write

Context

interface:Serial (DS1 FR-SUB L2, DS1 FR-SUB L2-L3)

Example

The following example creates and associates DLCI number 17 with the current sub-interface. This VC carries all traffic (if no priority dlci-group is defined for this interface), and becomes in the primary role.
Gxxx-001(super-if:Serial 3/1:1)# frame-relay interface-dlci 17