set responder

Last Updated : Nov 06, 2012 |
Specifies the responder port. A responder answers an incoming call and then plays a sequence of tones. The tones are used by test equipment at the other end of the loop to make measurements. The responder can be a port in the media module, or the Local Exchange Carrier (LEC).
Prolog information

Syntax

set responder {{slot port} | none}

Parameters

Parameter
Description
Possible Values
Default Value
slot
Number of the slot, represented as a number preceded by the letter v. For example, slot 1 is represented as v1.
A slot with an analog media module
port
Number of the port on the module, represented as two digits. For example, port 2 is represented as 02.
If you set the test port to be the responder port, the test port plays the role of the responder.
Any analog trunk port, including DID trunk ports
none
A keyword specifying that the Local Exchange Carrier (LEC) plays the role of the responder

User level

admin

Context

analog-test-profile

Example

Gxxx-001(analog-test-measure3)# set responder v302