show csu status

Last Updated : Nov 06, 2012 |
Displays the status of the CSU on a media module.
Prolog information

Syntax

show csu status mmID

Parameters

Parameter
Description
Possible Values
Default Value
mmID
The Media Module ID

User level

read-only

Context

general

Example

To display the status of the CSU on module 2:
Gxxx-001(super)# show csu status v2TI version of csu status:
CSU NETWORK INTERFACE STATUS
------------------------------------------------------------------
LOS:ON     00F:  OFF
EER:OFF    L00PD:  OFF
AIS:OFF    PDV:  OFF
LOF:OFF    YEL:  ON
E1 version of csu status:
CSU NETWORK INTERFACE STATUS
------------------------------------------------------------------
LOS:ON     00F:OFF
EER:OFF    L00PD:OFF
AIS:OFF    PDV:OFF
LOF:OFF    LMA:OFF
RMA:OFF    LCM:ON

Output fields

Name
Description
LOS
Loss of signal
OOF
Out of frame
EER
Excessive error rate
LOOPD
Looped
AIS
Alarm indication signal
PDV
Pulse density violation (same as BPV)
LOF
Loss of frame
LMA
Local multiframe alignment
YEL
Yellow
RMA
Remote multiframe alignment
LCM
Loss of CRC multiframe