Logon Failure Due to User ID/Password

Last Updated : Apr 29, 2020 |
Prolog information
This type of alarm details failed attempts to access the system.
Alarm
Description
Manager
This type of alarm occurs for a failed attempt to connect the IP Office Manager application to the system.
Monitor
This type of alarm occurs for a failed attempt to connect the System Monitor application to the system.
User
This type of alarm occurs for a failed user login.
Voicemail Box
This type of alarm occurs for a failed access attempt to a voicemail box.
Voicemail System
This type of alarm occurs for a failed attempt by a voicemail server to connect to the system. The system security settings can require the voicemail server to use a particular security password for connection.
SNMP
This type of alarm occurs if a management system attempts to execute an SNMP request using the wrong community string.
H.323 Extension
This type of alarm occurs if an invalid extension or passcode is been entered on the telephone during registration.
RAS
A dial-in user attempted to connect with the wrong password.
System Status
A login has been attempted from System Status with an invalid user ID or password.
If an alarm has additional information, System Status displays the following:
  • Logon failed due to incorrect userId/password.
  • Application: YYYYYYYYY
  • Additional information
The table below lists the additional information displayed for each login alarm type.
Logon Failure
Information
IP Office Manager
Operator name and the IP address of the PC running IP Office Manager
Monitor
IP address of the PC running Monitor
User
User number and name
Voicemail Box
User number and name
Voicemail System
IP address of PC running voicemail
SNMP
IP address of the host attempting SNMP access
H.323 Extension
User and extension number attempted
RAS
RAS user name
System Status
User name and the IP address of the host running System Status