R660xs Server FRU Replacement

Last Updated : Aug 18, 2025 |

This section describes how to replace a failed Avaya Solutions Platform (ASP) 130 Dell R660xs server in the field.

An ASP 130 server Field Replaceable Unit (FRU) comes with the system (BIOS) settings preconfigured for ASP 130 and base level firmware installed. Reference ASP 110 documentation for specific instructions on RAID configuration and BIOS/FW settings when replacing an ASP 110 server.

A server FRU is used for maintenance repair only. The Dell R660xs server FRU is a complete server replacement for Profiles A1, A2, A3 and contains all necessary components. Profile A31 has the same server FRU code as A3 but WILL require moving two HDDs from the failed A31 server FRU and require a reconfiguration of the RAID array to support the 8 HDD system.

This is different from the Dell R640 server FRU that only contains a subset of the components of the server it is replacing. Check the labels on the failed server to ensure the correct replacement server FRU is ordered.

Note:

For more information on importing drives from a failed server, see Chapter 32: Dell R660xs and R640 RAID Import Procedures.

ASP 130 R660xs Profile

Base Server FRU Material Code

Notes

A1

700519841

FRU comes with correct BIOS and RAID Configuration.

No components from failed server need to be moved.

A2

700519842

FRU comes with correct BIOS and RAID Configuration.

No components from failed server need to be moved.

A3

700519843

FRU comes with correct BIOS and RAID Configuration.

No components from failed server need to be moved.

A31

700519843

A31 has the same code as A3.

BIOS configuration is correct.

Two HDDs from failed server MUST be moved to the FRU server.

(No other components from failed server need to be moved.)

RAID configuration MUST be performed after two HDDs moved from failed server.