Internal Field Replaceable Units (FRUs) require the server to be shutdown and the cover removed to access and replace the FRU. All Virtual Machines running on the server should be gracefully shutdown prior to a graceful shutdown of the server itself.
FRU Part Number |
Internal field replacement units |
Hot-swappable? |
700514180 |
R640 1GbE QUAD PT INTEL NIC DAUGR CRD |
N |
700514184 |
R640 H730P MINI RAID CNTRLR |
N |
700514181 |
R640 ADDN 1GbE PCIE DUAL PT NIC – Half Height Faceplate |
N |
700514183 |
R640 DVD-ROM DRIVE W/BRKT |
N |
700514177 |
R640 CHASSIS FAN |
Y (will depend on physical server access as the server lid must be removed while server is running and may not be logistically possible.) |
700514188 |
R640 16GB Memory DIMM |
N |
700514187 |
R640 8GB Memory DIMM |
N |
700514186 |
R640 H730P RAID battery |
N |
700516329 |
R640 1GbE QUAD PT BROADCOM NIC DAUGR CRD |
N |
700516330 |
R640 ADDN 1GbE PCIE DUAL PT NIC – Full Height Faceplate |
N |
700516327 |
R640 H750 RAID CNTRLR |
N |
Note:
Components must be replaced like-for-like. Do not interchange RAID controllers or QUAD PT NDCs when performing replacements.
Note:
Customers must check the base server comcode and verify which RAID controller is in their system. Processes for replacement of a RAID battery differ based on the RAID controller, H730 vs H750.
The H730 RAID battery is a consumable item and therefore is considered a customer replaceable unit (CRU). The RAID battery is not covered under the maintenance agreement. Customer is responsible for the Avaya Solutions Platform server RAID Battery replacement.
The H750 RAID battery is not a separate orderable entity. In the event of a failure of the RAID Battery, the RAID Card will need to be ordered for replacement.
RAID Battery or RAID Card can be ordered from the Avaya Catalogue. It is possible to place an order to have Avaya perform the replacement.