Creating a Trunk group

Last Updated : Aug 03, 2018 |
Prolog information
  1. On the SAT session, in the Command terminal, type add trunk-group n and press Enter.
    ADDITIONAL INFORMATION:
    Where, n is the trunk group number.
    STEP RESULT:
    The system displays the TRUNK GROUP screen.
  2. Use the up or down arrow key and scroll to the Group Type option.
  3. In the Group Type option, type SIP and press the TAB key.
    ADDITIONAL INFORMATION:
    The system displays the TRUNK GROUP screen with information similar to the following:
    =========================================================================
    add trunk-group n                                     Page   1 of  22
                            TRUNK GROUP

    Group Number: 2              Group Type: sip       CDR Reports: y
    Group Name: trunk to ASM     COR: 1        TN: 1        TAC: #2
    Direction: two-way        Outgoing Display? n
    Dial Access? n                      Night Service:
    Queue Length: 0
    Service Type: tie                   Auth Code? n

                                        Signaling Group: 2
                                        Number of Members: 255
    =========================================================================
  4. Update the following values:
    Group Type
    sip
    Signaling Group
    Signaling group
    Note:
    You must configure the signaling group value that you created earlier.
    Number of Members
    The number of ports for this SIP connection.
    Service Type
    Tie
    TAC
    The trunk access code as per the dial plan.
  5. Press F7 key to go to the next page.
    ADDITIONAL INFORMATION:
    There are no changes required on screen 2.
  6. Press F7 key to go to the next page.
    ADDITIONAL INFORMATION:
    The page 3 of 22, displays the following information:
    =========================================================================
                                                        Page   3 of  22
    TRUNK FEATURES
       ACA Assignment? n            Measured: none
                                       Maintenance Tests? y



               Numbering Format: public
                                       UUI Treatment: shared
                                       Maximum Size of UUI Contents: 128
                                       Replace Restricted Numbers? n
                                       Replace Unavailable Numbers? n


                                  Modify Tandem Calling Number: no
                   Send UCID? y

     Show ANSWERED BY on Display? y
    =========================================================================
  7. Update the following values:
    UUI Treatment
    This value must be set to shared.
    Send UCID
    Set to Yes