Firmware specifications

Last Updated : Nov 03, 2023 |

New Comcode numbers for G430 Branch Gateway

Old codes are active for G430 Branch Gateway with the imbedded MP20 and MP80 bundle option.

  • 700503274 : G430 120 channel DSP daughter board – Single MP120 for upgrades

  • 700506957 : G430 MP120 Media Gateway – New bundle no on board MP20 and preinstalled MP120

  • 700506958 : G430 MP120 Media Gateway Non-GSA – New bundle number on board MP20 and preinstalled MP120

  • 700508198 : G430 120 CHANNEL DSP daughter board

  • 700512173 : G430 V3 40 CHANNEL GSA

  • 700512174 : G430 V3 40 CHANNEL NON-GSA

Minimum G430 Branch Gateway firmware requirements

Firmware version

Build

v1a

v2a

(MP120 Preinstalled)

v3

Comments

Recommended Communication Manager version

BGW 10.2

43.9.0

Yes

Yes

Yes

AA 10.2, CM 10.2

AA 10.1.x, CM 10.1.x

AA 10.1, CM 10.1

If your Branch Gateway is running Build 38.20.0 or earlier, you must install Release 7.1.0.4 Build 38.21.2 before upgrading to Build 43.9.0.

BGW 10.1

42.4.0

Yes

Yes

Yes

-

AA 10.1, CM 10.1

AA 8.1.x, CM 8.1.x

AA 8.0.x, CM 8.0.x

You can upgrade to Release 10.1 from Build 42.4.0 and earlier only after installing Release 7.1.0.5 Build 38.21.3.

BGW 8.1

41.9.0

Yes

Yes

Yes

MP120 Support

AA 8.1, CM 8.1

AA 8.0, CM 8.0

AA 7.1.x, CM 7.1.x

AA 7.0.x, CM 7.0.x +

You can upgrade to Release 8.1 from Build 41.9.0 and earlier only after installing Release 7.1.0.3 Build 38.21.1.

BGW 8.0

40.10.0

Yes

Yes

Yes

MP120 Support

AA 8.0, CM 8.0

AA 7.1.x, CM 7.1.x

AA 7.0.x, CM 7.0.x +

AA 6.3.x, CM 6.3.x +

You can upgrade to Release 8.0 from Build 40.10.0 and earlier only after installing Release 7.1.0.3 Build 38.21.1.

BGW 7.1.3

39.12.0

Yes

Yes

Yes

MP120 Support

AA 7.0 FP 1, CM 7.0.1

AA 7.0 FP 1, CM 7.0.1

AA 7.0, CM 7.0+

AA 6.2 FP 4, CM 6.3.6+

AA 7.1, CM 6.3.x, AA 7.0, CM 7.1.2

You can upgrade to Release 7.1.3 from Build 39.12.0 and earlier only after installing Release 7.1.0.3 Build 38.21.1.

BGW 7.1.2

39.x.y

Yes

Yes

No

MP120 Support

AA 7.0 FP 1, CM 7.0.1

AA 7.0 FP 1, CM 7.0.1

AA 7.0, CM 7.0+

AA 6.2 FP 4, CM 6.3.6+

AA 7.1, CM 6.3.x, AA 7.0, CM 7.1.2

You can upgrade to Release 7.1.2 from Build 39.5.0 and earlier only after installing Release 7.1.0.3 Build 38.21.1.

BGW 7.1.0+

38.16.0+

Yes

Yes

No

MP120 Support

AA 7.0 FP 1, CM 7.0.1

AA 7.0 FP 1, CM 7.0.1

AA 7.0, CM 7.0+

AA 6.2 FP 4, CM 6.3.6+

AA 7.1, CM 6.3.x, AA 7.0

Branch Gateway requires a 7.x build (37+) to successfully upgrade to Build 38.8.0 or later. Earlier builds will fail with the Invalid file error type. If Branch Gateway is running 36.x or earlier build, you must upgrade to 37.x.y before upgrading to 38.x.y.

BGW 7.0.1.2

37.41.0

Yes

Yes

No

MP120 Support

AA 7.0 FP 1

BGW 7.0.1.1

37.39.0

Yes

Yes

No

MP120 Support

AA 7.0, CM 7.0

BGW 7.0.1

37.38.0+

Yes

Yes

No

MP120 Support

AA 7.0 FP 1, CM 7.0.1

AA 7.0, CM 7.0+

AA 6.2 FP 4, CM 6.3.6+

BGW 7.0.0.2

37.21.0

Yes

Yes

No

MP120 Support

AA 7.0, CM 7.0

AA 6.2 FP 4 CM 6.3.6+

BGW 7.0.0.1

37.20.0

Yes

Yes

No

MP120 Support

AA 7.0, CM 7.0

AA 6.2 FP 4 CM 6.3.6+

BGW 7.0

37.20.0

Yes

Yes

No

MP120 Support

AA 7.0, CM 7.0

AA 6.2 FP 4 CM 6.3.6+

BGW 6.3.14+

36.18.0

Yes

Yes

No

MP120 Support

CM 6.3.x, AA 7.0

BGW 6.3.7 – 6.3.13

36.16.0+

Yes

Yes

No

MP120 Support

AA 6.2 FP 4 CM 6.3.6+

BGW 6.3.6 JITC

36.x.y

Yes

Yes

No

MP120 Support

AA 6.2 FP 4 CM 6.3.6

AA 6.2 FP3 CM 6.3.2+

(CM supports all 120 channels)

BGW 6.3.5

35.x.y

Yes

Yes

No

MP120 Support V150.1 Features

AA 6.2 FP3 CM 6.3.2+

(CM supports all 120 channels)

BGW 6.3.1

34.6.0

Yes

No

No

No BGW support MP120

AA6.2 FP3 CM6.3.2 – Oct 2013

(CM supports all 120 channels)

BGW 6.3

33.13.0

Yes

No

No

No BGW support MP120

AA 6.2 FP2 CM 6.3 – May 2013

(CM supports all 120 channels)

BGW 6.2.1

32.26.0

Yes

No

No

No BGW support MP120

AA 6.2 FP1 CM 6.2 sp 4 – Dec 2012

(CM blocks more than 105 channels)

BGW 6.1

31.26.0

Yes

No

No

No BGW support MP120

CM 6.0.1

(CM blocks more than 105 channels)