MM710B LEDs

Last Updated : Apr 02, 2020 |
Table 1: MM710B LEDs

LED

Name

Color

Indication

ALM

Alarm

Red

The module type is not the type configured in the MSG for the slot

TST

Test

Green

Either a test is being performed on the module via the server, or the module is performing a self-test upon initial insertion

ACT

Activity

Yellow

An E1/T1 trunk device connected to the module is in use.

The light is always on if the trunk is an ISDN E1 or T1 PRI trunk, and the MM710B is not configured as the synchronization source of the Branch Gateway.

The light flashes at a rate of 2.8 seconds on and 0.2 seconds off if the MM710B synchronization source is configured to synchronize the Branch Gateway and the module is receiving a T1 source signal.

The light flashes at a rate of 0.2 seconds on and 2.8 seconds off if the MM710B synchronization source is configured to synchronize the Branch Gateway and the T1 source is lost.

SIG

Signal

Green

The physical connection is up.