Interflow vector for NCR example

Last Updated : Sep 08, 2012 |

Communication Manager selects the site for call routing, and sends the call to the public network. The public network switch sets up a second leg of the call and passes the codeset 0 UUI information in the SETUP message, if this is supported. If you set the Net Redir field on the BSR Application screen to y for location 1, location 2, and location 3, Communication Manager sends a request to the public switch for call transfer over the public network.

For incoming 800 number calls from MCI DMS-250 network switches, you must ensure that the vector reached by the second leg call is answered immediately and an ISDN CONNect message is sent. This can be accomplished with a wait 0 secs hearing music or an announcement step as the first step in the receiving interflow vector.

BSR example of interflow vector on a remote Communication Manager

1. announcement    83345
2. consider split  2   pri m  adjust-by 0
3. consider split  11  pri m  adjust-by 0
4. queue-to best

The public network connects the second leg of the call to the second site and drops the trunk to Communication Manager.