Making a connection between Communication Manager and Call Management System

Last Updated : Dec 24, 2013 |

About this task

To receive the call center data from Communication Manager to Call Management System, you must establish a connection between Communication Manager and Call Management System. Add the communication-interface processor-channels between Communication Manager and Call Management System.

Procedure

  1. Log in to the Communication Manager system and select the SAT terminal type as SUNT.
  2. On the SAT session, in the Command: prompt, type change communication-interface processor-channels and press Enter.

    The system displays the change communication-interface processor-channels screen similar to the following:

    =========================================================================
    change communication-interface processor-channels       Page   1 of  24
    							PROCESSOR CHANNEL ASSIGNMENT
    Proc        Gtwy           Interface Destination     Session      Mach
    Chan Enable Appl. To Mode  Link/Chan Node       Port Local/Remote ID
      1:  y     mis     s     pv4 5000   CMS_server 0      1          1
      2:  n  
      3:  n                                                           0
    =========================================================================
  3. Use the up or down arrow key and scroll to a blank line.
  4. In the Enable column, type y.
  5. In the Appl. column, type mis.
  6. In the Mode column, type s.
  7. In the Link/Chan column, type pv4 5001 for procr.

    Set the channel value between 5000 to 64500 for Ethernet.

  8. In the Node column, type the node name of Call Management System.
  9. In the Port column, type 0.
  10. In the Local/Remote ID column, type 1 1.
  11. Press F3 key to save the changes.